Description
Product Overview:
| Features and Specifications | Details |
|---|---|
| Panel Options | Available from 16 to 32 Conventional zones |
| Programmability | Fully programmable inputs and outputs |
| Output Delays | Options for delays to the outputs |
| Alarm Reduction Modes | 3 different modes to help reduce false alarms |
| Standard Features | – Four monitored sounder circuits |
| – Fire & Fault VFCO relays | |
| – Fire, Fault, Reset & Disablement switched negative outputs | |
| – Class Change, Alert, Silence & Reset inputs | |
| Fully Functional Repeater Panel | Available via a plug-in comms PCB |
| Detector Compatibility | Supports a range of conventional detectors including Apollo, Hochiki & Nittan |
| Power Supply Module | 5.0 amp internal power supply module complies with EN54-4 : 1988 |
| Standards | Approved to European standards EN54-2 & 4, Fire Detection and Alarm Systems |
Main Features:
| Key Features | Details |
|---|---|
| Zones | 16 – 32 zones |
| Network | Network up to 8 control panels |
| Control Options | Activate controls via key switch or code entry |
| Monitoring | Integral detector removal monitoring |
| Power Supply | 5 Amp switch mode power supply Nom 27V DC |
| Sounder Outputs | 4 monitored sounder outputs |
| Relays | 2 Aux C/O relays (1 x Fire) (1 x Fault). Voltage-free |
| Inputs | Class Change, Alert, Silence Alarms & Reset switched -ve inputs |
| Outputs | Fire, Fault, Disablement & Reset, programmable switched -ve outputs |
| Delays | Program delays to outputs |
Specifications:
| General Information | Specifications |
|---|---|
| ADI Part Number | XL32-32 |
| Brand Name | Haes Technologies |
| Manufacturer | Haes Technologies Ltd |
| Manufacturer Part Number | XL32-32 |
| Product Line | Evoque |
| Product Model | XL32-32 |
| Product Name | Evoque XL32-32 Fire Alarm Control Panel |
| Product Type | Fire Alarm Control Panel |
Technical Information:
| Technical Details | Specifications |
|---|---|
| Number of Devices Supported per Zone | 512 |
| Number of Events Log | 40 |
| Number of Relays Supported | 2 |
| Number of Sounder Circuits | 4 |
| Number of Standard Zones | 32 |
| Panel Control Type | Conventional |
Battery Information:
| Battery Details | Specifications |
|---|---|
| Battery Voltage | 27.3 V DC |
| Battery Voltage (V DC) | 27.3 |
Physical Characteristics:
| Physical Details | Specifications |
|---|---|
| Colour | Silver |
Miscellaneous:
| Certifications & Standards | Details |
|---|---|
| CE | Yes |
| LPCB | Yes |
| TAA Compliant | No |